Main Page - Testing - Battery System Test
Testing

Battery System Test




Battery system test center consists of cell & module test chamber and battery system test chamber. These chambers hold world-class testing equipment and are capable of performing environmental performance test, heat management test and repeated cycle run lifespan test, etc., covering subjects ranging from single cells to full battery systems.




Cell & module test chamber  






Holds 10 environmental test chambers, cells (44 channels), modules (16 channels), capable of performing performance and lifespan tests for all types of cells (pouch, cylindrical, prismatic and solid state).


Testing capability


·Cell/module capacity and energy test
·Cell/module standard cycle and repeated cycle lifespan test
·Cell/module internal resistance test and degradation test

Equipment specs

Cell test (Arbin)

Voltage range:0-5V

Current range:0-1200A

Control accuracy:0.1%

Module test(Chroma)

Voltage range:0-100V

Current range:0-800A

Control accuracy:0.1%

Environmental test 

chamber

temperature range:-70~120℃

Volume:1000L









Battery system test chamber







Holds 4 walk-in environmental test chambers, 4 battery simulator (AVL), 2 dual channel battery coolant units, etc. Capable of performing performance tests and lifespan tests for battery systems.

Testing capability

·Cell/module capacity and energy test


·Cell/module standard cycle and repeated cycle lifespan test
·Cell/module internal resistance test and degradation test





Equipment specs


Temperature range

-70~120℃

Temperature tolerance

±1℃

Maximum power

500kW

Voltage range

0-1200V

Current range

0-800A

Control accuracy

0.1‰























Copyright 2024 © All Rights Reserved   Su ICP No.20028903-1  Technical Support :